Medical Physics Research - Medicine, Radiotherapy, Biomechanics, Medical Imaging

Medical Physics Research Today is a free monthly online journal that collates and summarizes the latest research about Medical Physics, including details on medicine, radiotherapy, biomechanics, medical imaging.


Medical Physics Research Today

Home

View Latest Issue

Information About Medical Physics

Books on Medical Physics

Advertising in Research Today

View Other Research Today Publications



Eight-row multidetector computed tomography coronary angiography evaluation of significant coronary artery disease in patients with severe aortic valve stenosis.

Holmström M, Sillanpää MA, Kupari M, Kivistö S, Lauerma K

Helsinki Medical Imaging Center, Helsinki University Central Hospital, Haartmaninkatu 4, 00029, Helsinki, Finland, Miia.holmstrom@hus.fi.

BACKGROUND: The aim of this study was to evaluate whether 8-row multidetector computed tomography coronary angiography (MDCT-CA) could replace invasive conventional coronary angiography (CCA) in patients with acquired severe aortic valve stenosis (AS). Coronary artery disease (CAD) diagnosis should be obtained with a noninvasive method in patients with AS undergoing valvular replacement. We evaluated the diagnostic accuracy of MDCT-CA in detecting high-grade (>/=50%) stenoses in the main coronary arteries in patients with AS. METHODS: Twenty-three patients with acquired severe AS underwent both CCA and MDCT-CA. We calculated the total and volumetric calcium scores and evaluated the image quality of each coronary segment as assessable or nonassessable for stenosis. The images of the arteries were evaluated for the occurrence of artifacts and the presence of high-grade stenoses (>/=50%) by visual estimation and comparison with that of CCA. RESULTS: Of the 322 segments screened 224 were assessable for stenosis. Heavy calcium load rendered 37 (38%) of the 98 coronary segments nonassessable. Compared to CCA, MDCT-CA had a sensitivity of 63%, a specificity of 96%, a positive predictive value of 52%, and a negative predictive value of 98% for >/=50% stenoses in the main coronary arteries. CONCLUSIONS: Eight-row MDCT-CA revealed a low sensitivity in detecting significant coronary artery disease in patients with acquired severe AS. High calcium burden decreased visualization of the lumen and complicated most often a correct assessment. In this patient group, CCA should still remain the primary pre-surgical test to rule out coronary lesions requiring revascularization.

Published 14 November 2006 in Int J Cardiovasc Imaging, 22(5): 703-10.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Medical Physics Research Today. All Rights Reserved.



Medical Physics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Medical Physics Books

Rad Tech's Guide to MRI: Basic Physics, Instrumentation, and Quality Control (Rad Tech Series)

Rad Tech's Guide to MRI: Basic Physics, Instrumentation, and Quality Control (Rad Tech Series)