Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging.

Mori S, Endo M, Kondo C, Tanada S

Department of Medical Physics and Medical Imaging, National Institute of Radiological Sciences, Chiba, Japan. shinshin@nirs.go.jp

RATIONALE AND OBJECTIVES: To improve effective scan time and image quality in cone-beam computed tomography (CT), Parker's weighting function (half scan [HS]-Feldkamp-Davis-Kress [FDK]) extended to a larger range up to 2pi was proposed as new half-scan algorithm (NHS-FDK). We conducted a practical physical evaluation of NHS-FDK and HS-FDK using 256-detector row CT. MATERIALS AND METHODS: Three types of weighting function (full-scan [FS-FDK], HS-FDK, and NHS-FDK) were evaluated by using 256-detector row CT for five variables, ie, point spread function, image noise, CT number uniformity, Feldkamp artifact, temporal resolution, and clinical evaluation. RESULTS: Image noise, Feldkamp artifact, and temporal resolution were dependent on weighting function. Image noise magnitude was independent of projection angle for all regions of interest with FS-FDK, but showed a symmetric pattern with projection angle with HS-FDK and NHS-FDK. With regard to temporal resolution, NHS-FDK did not remove the motion artifact in the heart except in such slower motion organs as the pulmonary vessels, whereas HS-FDK reduced the motion artifact in the heart. HS-FDK had an even more incomplete data region in the Radon space than FS-FDK, suggesting that it would provide poor image quality distant to the midplane in the longitudinal direction. In practical testing in human subjects, HS-FDK showed inferior performance in all variables except temporal resolution. CONCLUSION: Despite its inferiority to FS-FDK for static objects, HS-FDK may be useful in chest imaging. Contrary to previous findings using static images, NHS-FDK failed to show advantages over HS-FDK or FS-FDK in a moving phantom and human subjects.

Published 8 May 2006 in Acad Radiol, 13(6): 701-12.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Medical Physics Research Today. All Rights Reserved.



Medical Physics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Medical Physics Books

Cardiovascular MR Imaging: Physical Principles to Practical Protocols

Cardiovascular MR Imaging: Physical Principles to Practical Protocols