Medical Physics Research - Medicine, Radiotherapy, Biomechanics, Medical Imaging

Medical Physics Research Today is a free monthly online journal that collates and summarizes the latest research about Medical Physics, including details on medicine, radiotherapy, biomechanics, medical imaging.


Medical Physics Research Today

Home

View Latest Issue

Information About Medical Physics

Books on Medical Physics

Advertising in Research Today

View Other Research Today Publications



Assessment of radionuclide arthrography in the evaluation of loosening of knee prostheses.

Kitchener MI, Coats E, Keene G, Paterson R

Dr Jones and Partners Medical Imaging, C/o St Andrew's Hospital, 350 South Tce Adelaide SA 5000, Australia. bronton@senet.com.au

BACKGROUND: Radionuclide arthrography (RNA) is an established technique in the evaluation of hip prostheses but there is scant literature on its role in knee prostheses and no data specifically related to unicompartmental knee prostheses. We reviewed our experience with radionuclide arthrography in total (TKRs) and unicompartmental (UKRs) knee arthroplasties. METHODS: A retrospective review of 66 consecutive RNA studies that either had direct surgical correlation or arthroscopic assessment in conjunction with at least 12 months of clinical and radiological follow-up. These formed the basis of our case note review. 26 studies had a confirmed diagnosis of prosthetic loosening. RESULTS: By using standardised criteria for diagnosis and an early and late imaging protocol at 30 min and 4 h, RNA had an overall sensitivity of 88% and a specificity of 88% for the diagnosis of prosthetic loosening. The individual sensitivities and specificities were 93% and 86% for TKRs and 82% and 92% for UKRs. The technique was unable to detect femoral component loosening unless a long femoral stem was present, although only 8% of episodes of prosthetic loosening did not involve the tibial component. CONCLUSION: Radionuclide arthrography should be considered as a useful diagnostic test for the evaluation of loosening of the tibial component of knee prostheses but requires early and late imaging and close attention to detail to achieve optimal results.

Published 15 May 2006 in Knee, 13(3): 220-5.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Medical Physics Research Today. All Rights Reserved.



Medical Physics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Medical Physics Books

Past Life Regression: A Guide for Practitioners

Past Life Regression: A Guide for Practitioners