Medical Physics Research - Medicine, Radiotherapy, Biomechanics, Medical Imaging

Medical Physics Research Today is a free monthly online journal that collates and summarizes the latest research about Medical Physics, including details on medicine, radiotherapy, biomechanics, medical imaging.


Medical Physics Research Today

Home

View Latest Issue

Information About Medical Physics

Books on Medical Physics

Advertising in Research Today

View Other Research Today Publications



Does multi-detector row CT pulmonary angiography reduce the incremental value of indirect CT venography compared with single-detector row CT pulmonary angiography?

Ghaye B, Nchimi A, Noukoua CT, Dondelinger RF

Department of Medical Imaging, University Hospital Sart-Tilman, Domaine Universitaire du Sart-Tilman B 35, B-4000 Liège, Belgium. bghaye@chu.ulg.ac.be

PURPOSE: To compare retrospectively the incremental value of indirect computed tomographic (CT) venography performed after multi-detector row CT pulmonary angiography and single-detector row CT pulmonary angiography for the diagnosis of venous thromboembolism (VTE). MATERIALS AND METHODS: The institutional ethics committee approved this study; informed consent was not required. The authors retrospectively reviewed results of 1100 combined single-detector row CT pulmonary angiographic and indirect CT venographic examinations (542 men, 558 women; mean age, 61 years +/- 17 [standard deviation]) (group 1) and 308 combined multi-detector row CT pulmonary angiographic and indirect CT venographic examinations (150 men, 158 women; mean age, 62 years +/- 18) (group 2), performed in 1408 patients suspected of having pulmonary embolism (PE). Frequency of deep venous thrombosis (DVT), PE, and VTE, and the incremental value of indirect CT venography were recorded in both groups. Data were compared by means of the Student t test for continuous data and z statistics for independent proportions. RESULTS: VTE, PE, and DVT were found in 23.3% (n = 256), 19.9% (n = 219), and 18.3% (n = 201) of the 1100 patients in group 1, respectively, and in 23.7% (n = 73), 17.2% (n = 53), and 18.8% (n = 58) of the 308 patients in group 2, respectively (P values ranging from .273 to .876). The incremental value of indirect CT venography was 14.4% (37 of 256 patients) in group 1 and 27.4% (20 of 73 patients) in group 2. CONCLUSION: Despite potential improved accuracy of multi-detector row CT pulmonary angiography for the diagnosis of PE, the addition of indirect CT venography increased the diagnosis of VTE in 27.4% of patients.

Published 23 June 2006 in Radiology, 240(1): 256-62.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Medical Physics Research Today. All Rights Reserved.



Medical Physics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Medical Physics Books

Physics in Medical Diagnosis

Physics in Medical Diagnosis