Medical Physics Research - Medicine, Radiotherapy, Biomechanics, Medical Imaging

Medical Physics Research Today is a free monthly online journal that collates and summarizes the latest research about Medical Physics, including details on medicine, radiotherapy, biomechanics, medical imaging.


Medical Physics Research Today

Home

View Latest Issue

Information About Medical Physics

Books on Medical Physics

Advertising in Research Today

View Other Research Today Publications



Limited cone-beam computed tomography imaging of the middle ear: a comparison with multislice helical computed tomography.

Peltonen LI, Aarnisalo AA, Kortesniemi MK, Suomalainen A, Jero J, Robinson S

Department of Otorhinolaryngology and Department of Radiology, Helsinki University Central Hospital, Helsinki, Finland; HUS Helsinki Medical Imaging Center, University of Helsinki. Helsinki. Finland.

Purpose: To determine the applicability of cone-beam computed tomography (CBCT) in otological imaging, and to compare its accuracy with the routinely used multislice helical CT (MSCT) for imaging of the middle- and inner-ear areas. Material and Methods: Thirteen unoperated human cadaver temporal bones were imaged with CBCT and MSCT. Sixteen landmarks of the middle and adjacent inner ear were evaluated and compared for their conspicuity according to a modified Likert scale. Total scores and scores for subgroups including landmarks of specific clinical interest were also compared. Results: No significant differences were found between the imaging techniques or subgroups when scores of individual structures were compared. While the middle ear itself was visible in all cases with CBCT, parts of the inner ear were "cut off" in four cases due to the limited field of view. For the same reason, the evaluation of the whole mastoid was not possible with CBCT. The cochlear and vestibular aqueducts were not visualized in either CT techniques. The contrast-to-noise ratio was more than 50% lower in CBCT than in MSCT, but still adequate for diagnostic task. Conclusion: CBCT proved to be at least as accurate as routinely used MSCT in revealing the clinically and surgically important middle-ear structures. The results show that high-quality imaging of the middle ear is possible with the current CBCT device.

Published 13 March 2007 in Acta Radiol, 48(2): 207-12.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Medical Physics Research Today. All Rights Reserved.



Medical Physics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)



Medical Physics Books

Rad Tech's Guide to MRI: Basic Physics, Instrumentation, and Quality Control (Rad Tech Series)

Rad Tech's Guide to MRI: Basic Physics, Instrumentation, and Quality Control (Rad Tech Series)