Medical Physics Research Today is a free monthly online journal that collates and summarizes the latest research about Medical Physics, including details on medicine, radiotherapy, biomechanics, medical imaging. | ||||||||
|
Will 3D virtual dissection display prove to be the display format for reviewing CT colonography examinations?Glick S Department of Medical Imaging, Penn Presbyterian Medical Center, 39th and Market Streets, Philadelphia, PA 19104, USA. seth.glick@uphs.upenn.edu In the study by Kim et al, primary two-dimensional (2D) search with a three-dimensional (3D) problem-solving technique was compared with a 3D virtual dissection technique, with use of two independent reviewers. The authors observed no significant difference (P>.05) in sensitivity or specificity between the two techniques for the detection of polyps 6 mm or larger, whereas the median review time with virtual dissection was significantly (P<.05) shorter. This may have implications for the application of computed tomographic (CT) colonography for screening the asymptomatic average-risk population. Published 21 August 2007 in Radiology, 244(3): 629-30.