Medical Physics Research - Medicine, Radiotherapy, Biomechanics, Medical Imaging

Medical Physics Research Today is a free monthly online journal that collates and summarizes the latest research about Medical Physics, including details on medicine, radiotherapy, biomechanics, medical imaging.


Medical Physics Research Today

Home

View Latest Issue

Information About Medical Physics

Books on Medical Physics

Advertising in Research Today

View Other Research Today Publications



Absolute quantification of cerebral blood flow in normal volunteers: Correlation between Xe-133 SPECT and dynamic susceptibility contrast MRI.

Knutsson L, Börjesson S, Larsson EM, Risberg J, Gustafson L, Passant U, Ståhlberg F, Wirestam R

Center for Medical Imaging and Physiology, MR division, Lund University Hospital, Lund, Sweden.

PURPOSE: To compare absolute cerebral blood flow (CBF) estimates obtained by dynamic susceptibility contrast MRI (DSC-MRI) and Xe-133 SPECT. MATERIALS AND METHODS: CBF was measured in 20 healthy volunteers using DSC-MRI at 3T and Xe-133 SPECT. DSC-MRI was accomplished by gradient-echo EPI and CBF was calculated using a time-shift-insensitive deconvolution algorithm and regional arterial input functions (AIFs). To improve the reproducibility of AIF registration the time integral was rescaled by use of a venous output function. In the Xe-133 SPECT experiment, Xe-133 gas was inhaled over 8 minutes and CBF was calculated using a biexponential analysis. RESULTS: The average whole-brain CBF estimates obtained by DSC-MRI and Xe-133 SPECT were 85 +/- 23 mL/(min 100 g) and 40 +/- 8 mL/(min 100 g), respectively (mean +/- SD, n = 20). The linear CBF relationship between the two modalities showed a correlation coefficient of r = 0.76 and was described by the equation CBF(MRI) = 2.4 . CBF(Xe)-7.9 (CBF in units of mL/(min 100 g)). CONCLUSION: A reasonable positive linear correlation between MRI-based and SPECT-based CBF estimates was observed after AIF time-integral correction. The use of DSC-MRI typically results in overestimated absolute perfusion estimates and the present study indicates that this trend is further enhanced by the use of high magnetic field strength (3T). J. Magn. Reson. Imaging 2007;26:913-920. (c) 2007 Wiley-Liss, Inc.

Published 26 September 2007 in J Magn Reson Imaging, 26(4): 913-920.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Medical Physics Research Today. All Rights Reserved.



Medical Physics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Medical Physics Books

Questions and Answers in Magnetic Resonance Imaging

Questions and Answers in Magnetic Resonance Imaging